 Level Transmitter
- 4-20mA output signal
FlowLine offers the industry's most complete line of
engineered plastic level transmitters and relay controllers. To ensure broad and reliable
application coverage, we have developed an advanced range of complimentary technologies
including ultrasonic, alphasonic and RF capacitance devices. From bulk storage tanks to
OEM process baths, FlowLine has the right level transmitter for your application. Use
your PLC or FlowLine controller for exact level indication. |
 |
Ultrasonic Level
Transmitter - The Mini Me Two-Wire Ultrasonic level transmitter comes
in measurement depths of 10' for the LU12, 25' for the LU13 and up to 40'
for the LU14. Ideal for challenging corrosive, coating, or waste
liquids in atmospheric bulk storage tanks, day tanks, process vessels, and
waste sumps. All of the LU1X series level transmitters have a
Polycarbonate enclosure and have a PVDF/Kynar Transducer with a NEMA
rating of 6X. Can be used for processes with temperatures between
-40 and 160°F at up to 30 PSI. Viton mounting gasket and a 1"
NPT process mount for the LU12 and a 2" NPT process mount for the
LU13 and LU14. Extremely narrow 2" to 3" measurement beam
for tall, narrow tanks. Uses a 4-20 mA output signal that is easily
reversible for high current at top or bottom.
PDF files
Technical Bulletin
|
 |
Ultrasonic Level Transmitter
-Two or three wire control - 4-20mA output
The Echotouch™ ultrasonic level transmitter is offered in
two configurations for price and application flexibility. The LU30 series three-wire
transmitter provides reliable, non-contact measurement of liquids or slurries from 0.5 to
24.5 feet. The built-in 10 amp relay may be configured as an alarm or latched on two set
points for automatic pump or valve control. The LU30 series two-wire transmitter provides
reliable non-contact measurement of liquids or slurries from 0.5 to 16.5 feet. Both
compact transmitters are constructed of rugged polypropylene with a NEMA 4X enclosure and
PVDF transducer. With a narrow 8" beam width, digital display and push button
calibration, the Echotouch™ ultrasonic transmitter is the
process solution for non-contact level measurement.
PDF files
Technical bulletin
Installation manual
|
 |
Alphasonic Level
Transmitter - Two wire control - 4-20mA
output The
LA12 series Cricket™ alphasonic
transmitter functions on the ultrasonic principle and provides reliable, non-contact
measurement of liquids or slurries from 0.3 to 10 feet. Both compact transmitters are
constructed of rugged polypropylene with a NEMA 4X enclosure. The alpha sonic transmitters
are the low cost solution for level measurement in short range, OEM or process
applications. PDF files
Technical Bulletin - standard unit
Technical Bulletin for Intrinsically Safe unit
Installation manual
|
 |
RF Capacitance Level Transmitter
- The LP75 series RF capacitance level transmitter provides reliable, contact measurement
of conductive, non-coating or scaling liquids from 0.1 to 10 feet. The revolutionary
self-grounding probe does not require additional reference electrodes in plastic or
fiberglass tanks. Standard or custom probe lengths are available from 8" to
120". The compact transmitter is constructed of rugged polypropylene with a NEMA 4X
enclosure and FEP Teflon® probe. With an all plastic design
and self-grounding probe, the Symprobe™ RF capacitance
transmitter is the industrial solution for contact level measurement.
PDF files
LP10
Installation Manual
LP50 Installation Manual
LP75
Installation Manual
|
 |
Stainless Steel
Float Transmitter - The LV5X series level transmitter provides accurate
measurement, within 1/4 of an inch, of relatively clean water, light oils,
or diluted corrosives with a specific gravity of .75 or higher. Good
for high temperature and/or high pressure applications. Depth is
measured by a float from a range of 5 inches to 72 inches. May be
ordered with an explosion proof housing. Fitted with a 2" NPT
fitting plug and compatible with FlowLine remote indicator and relay
controllers. Depth readout output is a 4-20mA signal which is easily
reversible for high current at the bottom or top. Non-explosion
proof has a NEMA rating of 4X and the explosion proof LV51 has a NEMA
rating of 7P.
PDF files
Technical Bulletin
LV5 (0/1) S- Instruction Manual
|
|
|
FlowLine Level Controller |
 |
Continuous Relay
Controller - # LC52-1001 Features
Remote relay controller with up to three process set points, two relay
outputs and an isolated 4-20 mA repeater
Easy-Cal™ push button calibration for
placement of offset, span and relay set points
Digital display indicates current or engineering units
Fail-safe relays for actuation of pumps, valves or alarms
Bar graph indicates current reading as a percentage of span
0-60 second time delay dampens out relay chatter
LED indicators for power and relay output status
Invert switch provides simple NO or NC relay operation
Security lock out protects user defined set points
PP enclosure mounts on 35mm DIN rail or panel installation
Specifications for LC52-1001
- Instruction Manual
|
| ApplicationThe LC52-1001 level transmitter controller is commonly used for the automatic
filling or emptying of a tank between two set points with an additional high or low-level
alarm set point. A single latched relay performs the automatic pump or valve control,
while a second relay provides an independent alarm channel. Package this relay controller
with any of Flowline's two or three-wire level transmitters. |
Panel
Mounted Displays for Level Transmitters
|
 |
LI
10 - 1001
For AC powered indication and optional relay control, package the
universal panel meter with any of our level transmitters. The general
purpose DIN meter
(shown left) is
commonly used for the remote indication of tank level in custom
engineering units. The optional 2 or 4 relay outputs provide a variety of
process control functions with pumps, valves and alarms. With a built-in
power supply and optional analog repeater, the universal panel meter
offers a complete solution for single tank applications.
Details
|
 |
LI
20 - 1001
For
simple wiring and indication, package the loop powered panel meter with
any of our two-wire level transmitters. The general purpose meter is
commonly used for local or remote indication of tank level in custom
engineering units. Offered in two enclosure types, the panel mount version
(shown left) is 1/8 DIN and features a NEMA 4X faceplate. The outdoor
version is NEMA 4X with a rugged polycarbonate enclosure and clear
faceplate
Details |
PackagesFor automatic fill or empty applications with a high and low
level alarm, package the continuous relay controller with the Echotouch ultrasonic level
transmitter. The Echotouch transmitter has one built-in relay. In the example below left,
the Echotouch relay is configured on a single set point for a high-level alarm operation.
The continuous relay controller has two relays. Relay 1 is configured on a single set
point for a low level alarm operation. Relay 2 is configured on two set points for an
automatic fill operation. The repeater output is connected to the PLC for external process
information.
For automatic fill or empty applications, with a high or low level alarm,
package the continuous relay controller with the Symprobe RF capacitance level
transmitter. The continuous relay controller has two relays. In the example below right,
Relay 1 is configured on a single set point for a high-level alarm operation. Relay 2 is
configured on two set points for an automatic empty operation. The repeater output is
connected to the PLC for external process information.
New Battery Powered Level Transmitter with
Display
- Battery powered, so it doesn't require
remote power
- Accurately measures between 6 inches and 12
feet
- Power save
feature
Click Here for details
|
 |