LI20-1001 Loop Powered Panel Meter For simple wiring and indication, package the loop powered panel meter with any of our two-wire level transmitters. The general purpose meter is commonly used for local or remote indication of tank level in custom engineering units. Offered in two enclosure types, the panel mount version is 1/8 DIN and features a NEMA 4X faceplate. The outdoor version is NEMA 4X with a rugged polycarbonate enclosure and clear faceplate.
|
||||||||||||
Specifications - download PDF bulletin |
|||||||||||||
|
LI20-1001
Loop Powered Panel Meter |
|
|
Sensor
input: |
(1) transmitter |
|
Input
signal: |
4-20 mA |
|
Input
current: |
30 mA max. |
|
Voltage
drop: |
(panel): 1 VDC
2 20 mA |
|
Display
size: |
0.5 inch digits |
|
Accuracy:
|
0.05% of span |
|
Display
Type: |
LCD, 3.5 digit |
|
Calibration
range: |
4 mA:±5,000 |
|
Calibration
adjust: |
Potentiometer |
|
Temp.
rating: |
F: -40degreees
to 158 degrees |
|
CE
compliance: |
EN 50082-2
immunity |
|
Panel
Meter |
|
|
Enclosure
rating: |
1/8 inch DIN,
NEMA 4X faceplate |
|
Enclosure
material: |
High impact
plastic, |
|
Outdoor
Meter |
|
|
Enclosure
Rating: |
NEMA 4X |
|
Enclosure
window: |
Clear
polycarbonate |