Two-Way Direct Acting Solenoid Valves For Corrosive and Ultra-Pure Liquids |
|
Solenoid valves are designed using corrosion resistant thermoplastics and
premium elastomer seals to offer bubble tight shut-off service and million cycle
durability. Valves are normally closed when de-energized. The patented
Fail-Dry vented design with a secondary backup
diaphragm helps to avoid emergency shutdowns and gives a visual warning of potential
problems is standard on most models. Most valves are supplied with coils rated for
continuous service. Design - An electric solenoid coil is basically a simple electromechanical unit used to control the opening and closing of a valve. Energizing the coil creates a magnetic field which lifts the shaft and seat of the valve off its orifice. When de-energized a small spring pushes the shaft and seat down to close the valve. Response time is a split second. |
|
Coil
Selection
|
|
| Valve
Selection Criteria - Solenoid valve selection is a combination of selecting the
material of construction for the valve body, shaft seal type and elastomer. The
sizing of the valve is dependent upon the flow rate required through the valve, the
allowable pressure drop of the solution through the valve, the inlet pressure and back
pressure of the solution. We will assist in the selection process -- E-Mail: sales@kthsales.com Using electric solenoid valves for chlorine ? If so, read this. |
|
| Take me to actuated ball valves - I don't want a solenoid valve | |
|
|
|
|
|
|
|
|
EAST Series - Compact and Economical Teflon® Bellows |
|
|
![]()
|
| Pipe Size | Orifice | Cv | Max. Inlet Pressure* | Max. Back Pressure* | Watts | Model No. with PVC body |
| 1/4 1/2 |
3/16 | 0.5 | 140 | 70 | 11 | EAST2V6W11-PV EAST4V6W11-PV |
| 1/4 1/2 |
1/4 | 0.8 | 70 | 60 | 11 | EAST2V8W11-PV EAST4V8W11-PV |
| 1/4 | .375 | 1.1 | 140 | 38 | 20 | EASYMT2V12W20-PV |
| 1/2 | .375 | 1.1 | 140 | 38 | 20 | EASYMT4V12W20-PV |
| 1/2 | .375 | 2.1 | 125 | 18 | 20 | EASMT4V12W20-PV |
| 3/4 | .470 | 3.1 | 58 | 17 | 20 | EASMT5V16W20-PV |
| 1 | .452 | 3.6 | 25 | 12 | 20 | EASMT6V14W20-PV |
| 1 | .656 | 4.6 | 15 | 12 | 20 | EASMT6V22W20-PV |
| 1/2 | .375 | 2.3 | 140 | 38 | 58** | EASMT4V12G58-PV |
| 3/4 | .470 | 3.4 | 120 | 34 | 58** | EASMT5V16G58-PV |
| 1 | .656 | 4.7 | 70 | 34 | 58** | EASMT6V22G58-PV |
* Inlet pressure and back pressure for AC coils only - DC coils rating will be reduced by as much as 50% - contact us for details ** 58 watts coils - intermittent duty only. |
|
Need help in selection ? Call 1-800-235-3604 or E-Mail sales@kthsales.com |
When higher flow rates or higher pressures are required, a solution pressure pilot type valve will be used for desired results. PS Series - Pilot Operated Solenoid Valve for High Pressures and High Flow rates |