The Signet 2724 & 2726 pH and 2725
ORP Electrodes features a patented reference electrode design and uses the
unique foul-proof patented DryLoc® connector. The large area PE reference
junction and pathway is constructed to increase the total reference
effectiveness and ensures long service life.
The DryLoc connector with corrosion
resistant gold plated contacts readily connects the sensor to the mating 2760
preamplifier or the 2750 sensor electronics. The robust Ryton® threaded
sensor body and choice of flat pH, bulb pH, or flat ORP sensing elements
provides broad range of chemical compatibility for a wide variety of
applications.
There are two optional sensing
versions, -HF and -LC, available. The quick temperature response is available
in either a PT1000 or 3 KΩ temperature sensor and allows compatibility
with all Signet pH/ORP instruments. The 2724-2726 electrodes are
general-purpose sensors ideal for a wide range of applications. The sensors
incorporate ¾” NPT or ISO 7-1 R¾ threads for installing into standard
pipe-tees. They can also be mounted directly into Signet standard fittings.
Application:
- Water & Wastewater Treatment
- Neutralisation Systems
- Scrubber Control
- Effluent Monitoring
- Surface Finishing
- Heavy Metal Removal and Recovery
- Toxics Destruction
- Sanitization Systems
- Commercial Pools & Spas
- Aquatic Animal Life Support Systems
- Process Control
Key Benefits and Features:
- Ryton body for wide chemical
compatibility
- Porous UHMW PE junction resists
fouling
- Internal temperature sensor
- Mounts in 3/4" NPT connection
(optional ISO R3/4) or Signet flow installation fitting
- Mounts totally submerged via pre-amp
- LC for low conductivity solutions
(DI water)
- HF (for up to 2% HF) option for pH
Advantages:
- Designed for use with 2750 Sensor
- Foul-proof connector
- Gold-plated contacts
- Self-cleaning flat versions reduce
risk of glass breakage
- Large reference volume and solid
polymer electrolyte
Notes:
- Use with 2760 (3 KΩ) pre-amp
when using 5700 or 3-8750-xx instruments.
- Use with 2750 (PT1000) pre-amp when
using with Series 8900 instruments or for a direct 4-20mA output for
connection to PLC or other data recorders.
- 2724 is a flat glass surface pH
electrode providing a self-cleaning action and is best for abrasive /
slurry services -
- 2726 is a glass bulb pH electrode
- 2725 is a flat ORP electrode
download
2724-2725-2726 tech sheet
See below for special
purpose pH / ORP electrodes
2760 DryLoc® pH-ORP Preamplifiers and
2750 Connectors
The Signet 2750/2760 pH/ORP Preamplifiers
features the DryLoc® connector, providing a robust connection to Signet
DryLoc® electrodes. The DryLoc® electrode connector system
quickly forms a robust assembly for submersible and in-line installations.
NEMA 4X junction enclosures are to extend the preamplifier cable to long
distances.
Use 2760 with Signet pH or ORP
instruments - The 2760 preamplifier allows any DryLoc®
pH/ORP electrode to work with Signet ProcessPro® and ProPoint® pH/ORP
instruments. It is also sold as a simple connector for use with other
manufacturers’ instruments that do not require a preamplified signal. The 2760 submersible preamplifier can
also be used as an In-line preamplifier when used with the ¾ in. or 1 in.
threaded sensors including the 2724, 2774 and 2764 series electrodes. The 2760
In-line preamplifier can be used with Signet fittings up to DN100 (4 in.) and
wet-tap assemblies. download
2760 tech sheet
Using the 2750 as a
blind 4-20mA transmitter - additional details
Use 2750 for 4-20mA output or Signet
8900 controller - The 2750 preamplifier for use with
Signet 8900 (S3L) output or 4-20mA output. EasyCal provides for
calibration of electrode when using to provide a 4-20mA signal for a PLC or
other device. download
tech sheet
Advantages:
- In-line integral mount and
submersible installation versions
- Automatic temperature compensation
- Auto configuration for pH or ORP
operation
- Junction boxes for convenient wiring
Standards: CE
download 2750 tech sheet
download 2760 tech sheet
| 3-2760-1 |
Pre-amp with 3/4" FNPT threads |
for NPT fitting - inline or submerged (gray body) |
| 3-2760-11 |
Pre-amp for inline with Signet fitting or wet-tap |
Yellow body |
| 3-2750-1 |
Pre-amp for inline with 8900 |
Yellow body |
| 3-2750-2 |
Pre-amp for inline with EasyCal for 4-20mA output |
Yellow body |
| 3-2750-3 |
Pre-amp with 3/4" FNPT threads |
for NPT fitting - inline or submerged (gray body) |
2774-2777 Threaded DryLoc® pH-ORP
Electrodes
The Signet 2774 - 2777 pH and ORP
Electrodes feature a unique foulproof DryLoc® connector with goldplated
contacts designed specifically for use with the Signet 2750 and 2760
preamplifiers, sensor electronics, and connectors. These dependable and
highly responsive electrodes feature a PTFE double reference junction with
KNO3 in the front chamber to block various poisoning ions. Embedded
positioning of the temperature element in the pH sensing tip allows the
temperature response to be quick and accurate.
The electrodes are offered with
either flat or bulb style sensing elements. The flat versions allow
sediment and particles to sweep past the measurement surface, minimizing
risks of abrasion, breakage and coating. The bulb versions can be used for
general purpose applications. Due to the specially designed chambers which
keep electrolyte in place, all versions can be mounted at any angle, even
inverted.
Fields of Application:
- Water Treatment & Water
Quality Monitoring
- Demineralizer, Regeneration
& Rinse
- Cooling Tower and Boiler
Protection
- Aquatic Animal Life Support
Systems
- Pool and Spa Control
- Neutralization Systems
Advantages:
- Durable DryLoc connector with
gold plated contacts
- Special design allows mounting
at any angle
- Quick temperature response
- High temperature versions
available
- Easy sensor replacement using
DryLoc electrode connector
- Mounts into standard 3/4 inch
threads
Download
tech sheet 2774-2777
|
2764-2767 Differential DryLoc®
pH-ORP Electrodes
The Signet 2764-2767 Differential
pH & ORP electrodes are built with the DryLoc® connector a Ryton®
body and TeflonT reference junction to handle even the most extreme and
harshest of chemical applications.
These differential electrodes use
field-proven 3-electrode differential technique: the pH and reference
electrodes are measured against a ground electrode, ensuring a steady and
stable signal. A key feature is the reference electrode which is protected
in a glass half-cell embedded in the reference chamber and is protected
from compounds that may contain sulfides (S2-) and metals. To ensure long
service life, the reference features a refillable electrolyte chamber and
a replaceable equitransferant salt bridge. The patented porous PTFE
reference junction resists fouling, clogging and chemical attack.
Other elements of the design are
the solution ground, the pH/ORP electrodes, and the temperature element.
The solution ground eliminates noisy measurements by draining electrical
current away from the reference electrode. The pH/ORP electrodes are
designed with a flat or bulb measurement surface, and a temperature device
that is positioned at the tip of the measurement surface, making the
temperature response of T95% less than 1 minute. Various temperature
devices offered include 3 KΩ, 300Ω, or PT1000 RTD. The
electrodes are used with the Signet 2750 Sensor Electronics, which provide
a blind 4 to 20 mA output or use the digital (S3L) output to connect to
Signet's 8900 Multi-Parameter Controller. The electrodes can also be used
with the Model 2760 preamplifier to connect to the Signet's 5700 or 8750
instruments.
Fields of Application:
- Plating Baths
- Textile Dye Process
- Harsh Chemical Applications
- Heavy metal Removal and Recovery
- Toxics Destruction
- Surface Finishing
Advantages:
- Field-proven differential design
for stable measurements in the most aggressive applications
- Water-tight DryLoc connector
with foulproof gold contacts
- PTFE reference junction
- Rebuildable reference electrode
- Solution ground
- Integral temperature sensor.
Quick temperature response
- Easy sensor replacement using
DryLoc electrode connector
- Compatible with other suppliers'
instruments
Download
tech sheet 2764-2767
|
3719 pH-ORP Wet-Tap
The Signet 3719 pH/ORP Wet-Tap
allows installation and removal of pH or ORP electrodes (2756 /2756)
without the need for process shutdown during routine electrode maintenance
and calibration. Process isolation is achieved with a double O-ring seal
on a unique and compact retraction assembly; no separate valve is
required. A camactivated automatic locking mechanism, SafeLoc™, and the
short stroke design help to assure operator safety. The wet-tap unit can
be mounted at any angle and can be used with the Signet DryLoc Wet-Tap
electrode.
Fields of Application:
- Aquatic Animal Life Support
Systems
- Recreational Water Monitoring
- Water & Wastewater Treatment
- Effluent Monitoring
- Neutralization Systems
- Sanitisation Systems
- Pool and Spa Control
Advantages:
- Removes electrodes from
pressurized systems for routine service or replacement
- Automatic process isolation upon
electrode retraction - no separate valve required
- Space saving 45 mm (1.75 in.)
short-stroke design
- Sealed pneumatic dampening for
smooth and safe operation
- SafeLoc™: Camactivated
automatic locking mechanism (patent pending)
- Compatible with DryLoc
Electrodes for use with 2750 pH/ORP Sensor or 2760 DryLoc pH/ORP
Preamplifiers and Connectors
- Large reference volume for long
electrode life
- Protects electrode sensing
surface from breakage
- pH electrode includes integrated
temperature sensor
- Low profile Clamp-on Saddle
Fittings for convenient installation in ASTM pipe sizes 2.5 to 12 in.
Download
tech sheet 3719
Use 2756 pH electrode or 2757 ORP
|
2714 and
2716 CPVC body General Purpose Electrodes
NOTE
Model 3-2714 and 3-2716 pH electrodes
should not be used except as replacements. Until 2015.
Model 3-2715 and 3-2717 ORP electrodes
should not be used except as replacements. Until 2015
- the required 2-2720 pre-amp has been
discontinued as is NOT available from the factory - March2010
pH Probe - requires Pre-Amp - see below
Model 3-2714 - flat surface resists fouling -
for use in most industrial applications
Model 3-2714-HF - flat surface in applications
with trace hydrofluoric acid
Model 3-2716 - bulb type provides the best
choice for most applications for pool/spa and surface waters
Model 3-2716-DI - bulb type for use with pure
water
Signet 2715 / 2717 ORP electrode
Features
- Twist and lock with Pre-Amp (Model 2720)
- Double junction combination electrode
- Reference: Ag/AgCl
- Platinum sensing surface
- Porous UHMW polyethylene ref. junctions
- May be used inline or submerged
- CPVC construction - Double Viton O-Rings seals
3-2715 Flat ORP electrode - resists fouling
for most heavy industrial applications.
3-2717 Bulb ORP electrode - for general
service use.
Signet Model 2720 Pre-Amp
is now obsolete available in limited supply
- 3-2720 with 3/4" FNPT connection - Price:
$ 300.00 May 2010
Use with the above probes to increase the signal
strength that allows the probe to be mounted a great distance from the controller.
This device forms the top half of the twist and lock holder for the pH electrode. The CPVC
housing has a 3/4" FNPT thread that allows the probe assembly to be submerged.
Includes 15 foot cable - may extend up to 400 feet.
This pre-amp is also used with Model 2715 and
2717 ORP electrodes.
|