| Penguin magnetic driven pumps are
corrosion resistant to a wide range of chemical solutions including acids, alkalies and
caustics up to 180 degree F. There is no shaft seal, so there is no seal wear, leaking or
squeal. There is no seal friction to cause loss of pumping power. The only moving parts
inside the pump volute are the impeller magnet assembly and the bushing which rotates on
the pure ceramic spindle. Powerful impeller and drive magnets provide full torque, prevent
slippage and give instant start-up. Carbon impeller bushing can be provided as an
option -- this allows the pump to run dry with out damage for short periods of time. Materials of construction
Penguin magnetic driven pumps are constructed of polypropylene and/or Ryton (motor
bracket, impeller magnet assembly, encapsulated impeller assembly and pump housing),
carbon or chemloy or Ryton/Teflon (bushing), ceramic (spindle and thrust washers) and
Viton® O-ring. PVDF (Kynar) and stainless steel construction are available for most
sizes.
Motors
All motors (1/5 HP and larger) are TEFC - totally enclosed fan cooled. M1/14 and
M1/8 are blast cooled enclosure. Chemical Duty, air drive, explosion proof optional
motors are available for most sizes.
Self Priming
Model M-3/4 can be supplied as a self priming unit using a 1HP motor. Also as an option,
Penguin priming chambers can be supplied to other M series pumps to f acilitate priming the pump and reduce the danger of running the pump
dry. Mounted on a common polypropylene base, the priming chamber is piped directly to the
suction of the pump with a low valve on the pump discharge. Casters can be added for
portability. 316 SS and Kynar construction are available on most models.
Parts and Installation Sheet - Adobe
PDF file
Filtration Systems
Penguin Series SM and MF Filter Systems combine the M Series pump with filter systems.
Take me there. |