| Penguin Wound Filter
Cartridges Features:
|
![]() |
Greater Solids Holding Capacity Penguins wound cartridge filters are manufactured using a high speed, continuous wind process which creates a superior one-piece filter with hundreds of diamond shaped tunnels that get progressively smaller from the outer diameter to the core. Finer particles are progressively trapped as fluid travels to the center of the filter allowing for much greater retention capacity than that which is associated with straight surface filter media of the same dimensions and porosity. The winding pattern provides 3.5 square feet per 10" cartridge filter. For each 10" filter length there will be approximately ½ to 1 lb. Retention of solids before replacement becomes necessary. The amount of solids retained depends on the type of solids in the solution as well as the head pressure developed by the pump. Wide Choice of Porosity, Lengths and Diameters Our wound cartridge filters reject particles from as low as 0.5 micron to 150 micron plus they are available in lengths ranging from 4" to 40" or longer on special order. We offer a standard nominal 1" inside diameter and optional inside diameters of 7/8", 1 3/8", and 30 mm. Our outside diameter is 2 ½" standard with optional outside diameters ranging from 2" to 4 ½". Thus you can tailor your filtration system to your specific needs and economics whether it be for single pass or recirculation filtration. Temperature and Chemical Compatibility Penguin offers a wide selection of wind and core materials so you can select the appropriate combination for your filtration needs. Wind materials include: Standard, fibrillated and utility grade polypropylene, natural cotton, bleached cotton, rayon, polyester, nylon, modacrylic and heat cleaned glass fiber. And core materials includes: polypropylene, tin plated steel, 304 stainless steel and 316 stainless steel. Longer Service Life Penguins wound cartridge filters offer true depth filtration for high dirt holding capacity and extremely low media migration. Thus, even when the particle distribution of the contaminant is broad, Penguin filters have excellent dirt holding capacity because of density and structure. Therefore, it is not unusual for a set of cartridges to filter many millions of gallons of fluid before requiring replacement. This means less equipment downtime, extended life for chemical solutions, cleaners, oils, coolants and liquids, not to mention the savings in labor and materials. |
Series PF-P - Standard Polypropylene |
|
| Recommended for concentrated acids and alkalies, strong oxidizing agents, corrosive fluids and gases. FDA and Non-FDA available-consult factory. Easily incinerated to trace of ash. Excellent micro-organism resistance. For use to 200o F. | |
|
|
| Series PF-X Fibrillated Polypropylene -"Electronic Grade" | |
| Non-migrating slit film polypropylene free of extractables recommended for use in ultra-pure liquids, electronics, and plating where non-leaching is critical. No extractables or sizing agents present. Chemical resistance equal to standard polypropylene. Low moisture absorption and outstanding abrasion resistance. Lowest static propensity of any man-made fiber. High dry or wet strength. | |
|
|
| Series PF-UGP Utility Grade Polypropylene | |
| Same applications as standard polypropylene but less consistency in appearance due to discoloration, nicknamed "rainbow". For use to 200 o F. Primarily used in wastewater treatment. | |
|
|
| Series PF-M Modacrylic (Dynel) | |
| For strong acids, concentrated alkalies, oxidizing agents. For use to 200o F. Not recommended for organic solvents. | |
|
|
| Series PF-K Polyester | |
| Chemical resistance similar to polypropylene, with high temperature resistance. For use to 350o F. | |
|
|
Series PF-C Bleached Cotton |
|
| Bleached to meet FDA standards for distilled water, beverages, vegetable oils, petroleum, fatty acid and alcohols. For use to 300o F. Poor micro-organism resistance. | |
|
|
Series PF-U Natural Cotton |
|
| For oils, water, paints, organic solvents, alcohol, petroleum. Non-FDA, for use to 300o F | |
|
|
Series PF-G Heat Cleaned Glass Fiber |
|
| Trace of oil sizing removed by heat cleaning, to yield virgin glass fiber. Recommended for high temperatures and high corrosion applications. For use to 750 o F. | |
|
|
Series PF-R Rayon |
|
| Fluid compatibility similar to bleached cotton but has coarser fiber and is less absorbent than cotton. Swells in aqueous solutions. For use to 300 o F. | |
|
|
Series PF-N Nylon |
|
| For special process applications, concentrated alkalies, and hydrocarbons. Excellent micro-organism resistance. For use to 300 o F. | |
|
|
| Series PS Polypropylene Felt Filter Sleeve System | |
|
|
Core Selection Guide Polypropylene Economical core of choice for most applications in water and corrosives to 200o F. Tin Plated Steel General purpose metal core for oils, solvents, paints and other non-FDA applications. For use to 400o F. 304SS For high temperature applications on diluted acids and moderately corrosive fluids. FDA applications. For use to 750o F. 316SS For high temperature
applications on strong acids and highly corrosive fluids. FDA applications. For use to 750o
F. |
| Filter Cartridge Nomenclature | |||||
| PF | P | 15 | R | 10 | P |
| Penguin Filter | Filter Media P = polypro |
Micron 0.5 |
Tube OD R = 2½" (standard) A = 2" B = 2 3/8" C = 2 ¾" |
Length 4 = 4" |
Core
material P = polypropylene T = tin steel S = 304SS A = 316SS |
| Micron Ratings Tubes are precision
wound to specified patters and tensions to insure repetitive results in filtration. Tube
rating are available (for most materials) in the following micron ratings: 0.5m m, 1, 3,
5, 10, 15, 20, 25, 30, 40, 50, 75, 100 and 150m m. Cases Tubes are packed in standard case lots of 30 for length of 4" to 12 15 for 20" to 30" and 10 for 40" lengths. Download Bulletin - PDF file Carbon Tubes ? Pleated Filters for higher flow rates |