Penguin PM Series Mixer
Penguin offer economical mixers using a high
shear type propeller. The usage of high speed drive motors at 1750 RPM, produces
rapid solution movement while utilizing smaller diameters. The mixer shaft is
a direct driven from the motor. The combination produces a lower cost mixer suitable
for most applications that solution shear is not a concern.
 |
Mounting
- Clamp Mount - allows the mixer to be mounted on the
tank side wall or another vertical surface. The bracket (pictured) allows for
adjustment of the propeller for maximum efficiency.
- Bracket Mount - provides a sturdy CPVC plate for
mounting the mixer on a cover or other flat surface.
- Thread Mount - a 2" PVC nipple is provided to
direct mount in the bung hole (pictured) of a drum or other 2" FNPT connection such
as a bulkhead fitting. This is usually combined with the 2" diameter turbine
propeller.
- Flange Mount - offers a companion flange to the above
for mounting in a cover or other flat surface.
Propeller construction
- CPVC Turbine - for mounting through a 2" opening
- Polypro Propeller - available in 3" or 4"
diameter
- 316SS Propeller - available in 3", 4" or
5" diameter
- Dual Propellers - available as required
Shaft
- All shafts and couplings are 316SS - 1/2 or
5/8"diameter
- Option - the shaft can be sleeved in polypro
(only with the polypro propeller)
- Length - Maximum determined by motor horsepower - see
below.
|
Mixer Sizing Data - The following is
useful general mixing of liquids within a tank - Consult if using for powders of viscous
liquids above 100 Cp. For efficient mixing, the recommended tank turn over rate is
6 to 10 turns per hour - the gallon per hour mixing time for each impeller is listed in
the chart below. The horsepower for the motor is determined by the specific gravity
of the solution - the required horsepower would be the result of water horsepower
(required) times the specific gravity. The shape of the tank determines a
requirement for dual impellers - use dual impellers if height of the tank is greater that
the diameter (or longest side in the case of a square or rectangular shaped tank).
Contact KTH Sales if you have any questions.
| Tank
Capacity |
Mixing
rate in GPH |
Diameter
|
Min.
Power * |
| 72 -
120 gallons |
720 |
2"
Turbine - CPVC** |
1/20 HP |
| 48 - 80
gallons |
480 |
3"
propeller |
1/20 HP |
| 108 -
180 gallons |
1080 |
4"
propeller |
1/4 HP |
| 228 -
380 gallons |
2280 |
5"
propeller - 316SS |
1/2 HP |
*
Multiply the above HP by the Specific Gravity of the liquid being mixed to determine the
actual HP required.
** The 2" CPVC turbine is designed to fit into a 2" FNPT bung hole. |
| Motor
HP |
Shaft
Dia. Length |
RPM |
Voltage |
Phase |
| 1/20 |
1/2"
x 28" |
1500 |
115V |
single |
| 1/4 |
1/2"
x 34" |
1725 |
115/230V |
single |
| 1/3 |
1/2"
x 36" |
1725 |
115/230V |
single |
| 1/2 |
5/8"
x 36" |
1725 |
115/230V 230V/460V |
single three |
| 1 |
5/8"
x 44" |
1725 |
115/230V 230V/460V |
single three |
All motors are TEFC as a standard
--Explosion Proof or air motors upon request |
Bulletin - PDF
Mixing
Eductors - better utilization of your pump for solution movement.
|